  • NAMECODEDESCRIPTIONW/H/DKGRETAILSPEC
    Nomad - Dual port/tracking MPPT Solar charge controller - 92% local content (South Africa)
    Nomad 85.0H
    85A 30min @25℃
    80A continuous @30℃
    FG-MP-AA 80A @30℃ with adjustable current limit (40A per PV input). 400Vdc absolute maximum / 375Vdc operating maximum. Bulk, absorption, float, and equalization. 20 to 63Vdc user adjustable with password protection (445/295/254)
    380/210/150
    (6.6)
    6.2
    R 14 950
    PowerStar - True bi-directional, True Sine Wave, Grid Interactive Inverter - 86% local content (South Africa)
    PowerStar 8.0H
    8kVA 30min @25℃
    6kVA continuous @30℃
    FG-PS-AA-I (36V)
    FG-PS-AH-I (48V)
    36/48V, 100A battery charger, single phase, modular, 2 AC input sources (grid and/or generator), DC measurement (solar or wind) 1.6m x 50mm² battery link. Minimum recommended battery size: 200Ah @ C20 (660/660/510)
    550/640/500
    (79.5)
    77
    R 52 030
    PowerStar 10.0H
    10kVA 30min @25℃
    8kVA continuous @30℃
    FG-PS-AB-I
    FG-PS-AK-I (60Hz, 277V)
    48V, 150A battery charger, single phase, modular, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 70mm² battery link. Minimum recommended battery size: 200Ah @ C20 (660/660/510)
    550/640/500
    (84)
    81
    R 59 510
    PowerStar 15.0H
    15kVA 30min @25℃
    12kVA continuous @30℃
    FG-PS-AC-I (36V)
    FG-PS-AI-I (48V)
    36/48Volt, 200A battery charger, single phase, modular, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 50mm² battery link. Minimum recommended battery size: 350Ah (600/960/510)
    550/945/500
    (150)
    145
    R 88 550
    PowerStar 18.0H
    18kVA 30min @25℃
    16kVA continuous @30℃
    FG-PS-AD-I 48V, 300A battery charger, single phase, modular, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 70mm² battery link. Minimum recommended battery size: 350Ah @ C20 (600/960/510)
    550/945/500
    (157)
    150
    R 108 680
    PowerStar 21.0H
    21kVA 30min @25℃
    18kVA continuous @30℃
    FG-PS-AC-I (36V)
    FG-PS-AI-I (48V)
    36/48Volt, 300A battery charger, three phase, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 50mm² battery link. Minimum recommended battery size: 500Ah @ C20 (600/960/510)
    550/945/500
    (218)
    209
    R 152 130
    PowerStar 27.0H
    27kVA 30min @25℃
    24kVA continuous @30℃
    FG-PS-AF-I
    FG-PS-AG-I (60Hz, 277V)
    48V, 450A battery charger,three phase, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 70mm² battery link. Minimum recommended battery size: 500Ah @ C20 (600/960/510)
    550/945/500
    (232)
    221
    R 164 230
    Oasis - Advanced True Sine Wave offline UPS, high performance battery charger - 84% local content (South Africa)
    Oasis 4.0H
    4kVA 30min @25℃
    3kVA continuous @30℃
    FG-OA-AA 3000VA 24Volt off-line UPS: pure sine wave inverter with 40A battery charger, ideal for off-grid use with generator & PV, or on-grid with pre-paid meter & PV. 1.6m x 50mm² battery link (440/665/300)
    360/585/215
    (40)
    38
    R 20 753
    Oasis 5.0H
    5kVA 30min @25℃
    4kVA continuous @30℃
    FG-OA-AB (36V)
    FG-OA-AC (48V)
    4000VA 36/48Volt off-line UPS: pure sine wave inverter with 50/40A battery charger, ideal for off-grid use with generator & PV, or on-grid with pre-paid meter & PV. 1.6m x 50mm² battery link (440/665/300)
    360/585/215
    (45)
    43
    R 23 421
    Oasis 7.0H
    7kVA 30min @25℃
    6kVA continuous @30℃
    FG-OA-AD (36V)
    FG-OA-AE (48V)
    6000VA 36/48Volt off-line UPS: pure sine wave inverter with 70/60A battery charger, ideal for off-grid use with generator & PV, or on-grid with pre-paid meter & PV. 1.6m x 50mm² battery link. Minimum recommended battery size: 200Ah @ C20 (480/740/310)
    400/660/220
    (65)
    62.5
    R 35 140
    Accessories - 91% local content
    Remote Monitoring and Control
    FG-RC-AA The MLT Bridge offers full remote monitoring and control and functionality. It operates off the DC backup to ensure the connection. Input voltage 15V-75V. It is compatible with the Powerstar, Nomad and Oasis series. Online subscription is free. WIFI/3G options available. 80/50/403R 2 980
    63A Single Phase Bypass Box
    FG-AO-AA 2 pole bypass (changeover) box for 3/4/6/8kVA 1-phase Oasis & PowerStar inverters, with alternative supply indicator 320/320/1703R 3 988
    150A Single Phase Bypass Box
    FG-AO-AB 2 pole bypass (changeover) box for 12/16kVA 1-phase PowerStar inverters, with alternative supply indicator 320/320/1707R 13 150
    75A Three Phase Bypass Box
    FG-AO-AC 4 pole bypass box for three phase 18/24kVA 3-phase Powerstar inverters, with alternative supply indicator for each phase 460/430/1607R 13 750
    Karoo - Dual port grid-tied or hybrid solar/battery/generator inverter - 82% local content (South Africa)
    Karoo 70.0C
    70kVA continuous @30℃
    FG-KR-AB The Karoo inverter range offers compact, high performance & efficient power solutions to the commercial, industrial and IPP market. High-voltage DC and transformer-less design guarantees highly efficient solar PV operation, assisting either the grid or generator. The storage-based configuration of the Karoo offers unique features like power factor compensation. (1000/1500/500)
    860/1309/358
    350R 275 220
    Karoo PV combiner box
    FG-AO-AP PV combiner box with MC4 connectors, connecting up to 16 PV strings to 2 DC buses. 1000Voc, Class 2 surge protection. Includes DC disconnect. (630/840/300)
    630/840/300
    30R 35 571
    Add class 2 lightning surge arrestors - per DC port
    Add class 1+2 lightning surge arrestors - per DC port
    FG-AO-AQ
    FG-AO-AW

    <1R 4 632
    R 9 547
    Karoo AC IsolatorFG-ACC-KA2 125A, three phase isolator switch to disconnect mains from inverter, within enclosure
    <1R 2 714