NAMECODEDESCRIPTIONW/H/DKGRETAILSPEC
Oasis - Advanced True Sine Wave offline UPS, high performance battery charger - 84% local content (South Africa)
Oasis 5.0H
5kVA 30min @25℃
4kVA continuous @30℃
FG-OA-AB (36V)
FG-OA-AC (48V)
4000VA 36/48Volt off-line UPS: pure sine wave inverter with 50/40A battery charger, ideal for off-grid use with generator & PV, or on-grid with pre-paid meter & PV. 1.6m x 50mm² battery link (440/665/300)
360/585/215
(45)
43
R 23 421
Oasis 8.0H
8kVA 30min @25℃
6kVA continuous @30℃
FG-OA-AD (36V)
FG-OA-AE (48V)
6000VA 36/48Volt off-line UPS: pure sine wave inverter with 70/60A battery charger, ideal for off-grid use with generator & PV, or on-grid with pre-paid meter & PV. 1.6m x 50mm² battery link. Minimum recommended battery size: 200Ah @ C20 (480/740/310)
400/660/220
(65)
62.5
R 35 140
Nomad - Dual port/tracking MPPT Solar charge controller - 92% local content (South Africa)
Nomad 90.0H
90A 30min @25℃
80A continuous @30℃
FG-MP-AA 80A @30℃ with adjustable current limit (40A per PV input). 400Vdc absolute maximum / 375Vdc operating maximum. Bulk, absorption, float, and equalization. 20 to 63Vdc user adjustable with password protection (445/295/254)
380/210/150
(6.6)
6.2
R 14 950
PowerStar - True bi-directional, True Sine Wave, Grid Interactive Inverter - 86% local content (South Africa)
PowerStar 8.0H
8kVA 30min @25℃
6kVA continuous @30℃
FG-PS-AA-I (36V)
FG-PS-AH-I (48V)
36/48V, 100A battery charger, single phase, modular, 2 AC input sources (grid and/or generator), DC measurement (solar or wind) 1.6m x 50mm² battery link. Minimum recommended battery size: 200Ah @ C20 (660/660/510)
550/640/500
(79.5)
77
R 52 030
PowerStar 10.0H
10kVA 30min @25℃
8kVA continuous @30℃
FG-PS-AB-I
FG-PS-AK-I (60Hz, 277V)
48V, 150A battery charger, single phase, modular, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 70mm² battery link. Minimum recommended battery size: 200Ah @ C20 (660/660/510)
550/640/500
(84)
81
R 59 510
PowerStar 15.0H
15kVA 30min @25℃
12kVA continuous @30℃
FG-PS-AC-I (36V)
FG-PS-AI-I (48V)
36/48Volt, 200A battery charger, single phase, modular, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 50mm² battery link. Minimum recommended battery size: 350Ah (600/960/510)
550/945/500
(150)
145
R 88 550
PowerStar 18.0H
18kVA 30min @25℃
16kVA continuous @30℃
FG-PS-AD-I 48V, 300A battery charger, single phase, modular, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 70mm² battery link. Minimum recommended battery size: 350Ah @ C20 (600/960/510)
550/945/500
(157)
150
R 108 680
PowerStar 21.0H
21kVA 30min @25℃
18kVA continuous @30℃
FG-PS-AC-I (36V)
FG-PS-AI-I (48V)
36/48Volt, 300A battery charger, three phase, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 50mm² battery link. Minimum recommended battery size: 500Ah @ C20 (600/960/510)
550/945/500
(218)
209
R 152 130
PowerStar 27.0H
27kVA 30min @25℃
24kVA continuous @30℃
FG-PS-AF-I
FG-PS-AG-I (60Hz, 277V)
48V, 450A battery charger,three phase, 2 AC input sources (grid and/or generator), DC measurement (solar or wind), 1.6m x 70mm² battery link. Minimum recommended battery size: 500Ah @ C20 (600/960/510)
550/945/500
(232)
221
R 164 230
Accessories - 91% local content
Remote Monitoring and Control
FG-RC-AA The MLT Bridge offers full remote monitoring and control and functionality. It operates off the DC backup to ensure the connection. Input voltage 15V-75V. It is compatible with the Powerstar, Nomad and Oasis series. Online subscription is free. WIFI/3G options available. 80/50/403R 2 980
63A Single Phase Bypass Box
FG-AO-AA 2 pole bypass (changeover) box for 3/4/6/8kVA 1-phase Oasis & PowerStar inverters, with alternative supply indicator 320/320/1703R 3 988
150A Single Phase Bypass Box
FG-AO-AB 2 pole bypass (changeover) box for 12/16kVA 1-phase PowerStar inverters, with alternative supply indicator 320/320/1707R 13 150
75A Three Phase Bypass Box
FG-AO-AC 4 pole bypass box for three phase 18/24kVA 3-phase Powerstar inverters, with alternative supply indicator for each phase 460/430/1607R 13 750
Karoo - Dual port grid-tied or hybrid solar/battery/generator inverter - 82% local content (South Africa)
Karoo 70.0C
70kVA continuous @30℃
FG-KR-AB The Karoo inverter range offers compact, high performance & efficient power solutions to the commercial, industrial and IPP market. High-voltage DC and transformer-less design guarantees highly efficient solar PV operation, assisting either the grid or generator. The storage-based configuration of the Karoo offers unique features like power factor compensation. (1000/1500/500)
860/1309/358
350R 275 220
Karoo PV combiner box
FG-AO-AP PV combiner box with MC4 connectors, connecting up to 16 PV strings to 2 DC buses. 1000Voc, Class 2 surge protection. Includes DC disconnect. (630/840/300)
630/840/300
30R 35 571
Add class 2 lightning surge arrestors - per DC port
Add class 1+2 lightning surge arrestors - per DC port
FG-AO-AQ
FG-AO-AW

<1R 4 632
R 9 547
Karoo AC IsolatorFG-ACC-KA2 125A, three phase isolator switch to disconnect mains from inverter, within enclosure
<1R 2 714
Microgrid Site Controller - Advanced Site Management - 92% local content (South Africa)
MSC Master
Microgrid Site Controller Master
FG-MG-AA Each microgrid requires one Microgrid Controller, which communicates over an Ethernet network with up to sixty-three Microgrid Extenders on the site, with directly-controlled microgrid control entities (loads, inverters and generators) and with MLTs internet portal.
The controller has the same control and measurement ports as the Microgrid Extender. It also includes a large LCD touchscreen which allows local monitoring and configuration, an Ethernet hub, and optionally an internal UPS. External contactors, CTs and an existing Ethernet network are required for this device. The module is housed in an IP65 rated sheet-metal enclosure.
R 28 900
MSC Extender
Microgrid Site Controller Extender
FG-MG-AB Extends MSC Master. Extends same monitoring and control ability for additional site control. Typically used on large sites for cluster control. R 24 900